DeviceMaster UP DB9M 2-Port 1E Modbus

Key Features:

The DeviceMaster UP DB9M 2 Port 1E Modbus is an industrial Ethernet Gateway designed to provide connectivity between a vast array of Modbus controllers and devices.
This gateway is quickly to setup and easy to be used even with complex Modbus installation as it has a simplified configuration pages innovative functionality and informative diagnostic information.

• DIN-rail mounting and screw terminal power connections
• Highly flexible and unique Modbus functionality
• Multiple Modbus master and slave types
• Raw/ASCII Serial and Ethernet device support
• Variable power input eliminates need for power converters
• Dual Ethernet ports for daisy chaining network connections between multiple units (2E model)
• PortVision® DX monitoring and management software
• RoHS2 compliant under CE

Product Details

Hardware


Bus Interface Specification 10/100BASE-T
Memory
– SDRAM 8MB
– Flash 4MB
Enclosure UL94-V0 PLASTIC
Installation Method DIN Rail (35mm)
LED Indicators ETHERNET ACTIVITY, ETHERNET LINK, and STATUS
Dimensions
– 4.6″ x 3.9″ x 0.9″
– 116.8 x 99 x 22.9 mm
Product Weight
- 4.6 oz
– 130.41 g

Electrical Specifications


Device
DC Input Voltage 6-30V
Current Consumption +24VDC65mA
Power Consumption (maximum)1.56 W
Power Input Redundancy Dual Redundant Power Input
ESD Surge Protection Provided minimum of 25KV protection for all serial lines. All Ethernet components are rated to 1.5KV magnetic surge protection.

Environmental Specifications


Air temperature
– System On -37 to 74° C
– System Off -40 to 85° C
Operating Humidity (non-condensing) 5% to 95%
Altitude 0 to 10,000 Feet
3,048 m
Heat Output 5.3 BTU/Hr
MTBF (Mean Time Between Failures) 58.8 Years

Serial Communications


Connector Type DB9 Male
Number of Ports 2
Software Interfaces
– RS-232
– RS-422
– RS-485 2-Wire
– RS-485 4-Wire (Master/Slave)
Baud Rate 300 bps to 230.4 Kbps
Receive Buffer 1024bytes
Transmit Buffer 256bytes
Device Driver Data Control
Data Bits 7 or 8
Parityodd, even, or none
Stop Bits1 or 2
Flow ControlHardware, Software, or None

Communication Modes


• Modbus TCP/RTU/ASCII to raw/ASCII Serial or Ethernet TCP/IP
• Modbus/TCP to Modbus RTU/ASCII
• Modbus RTU/ASCII (Auto Locate and Auto Route)
• Raw/ASCII Data Stream and Command/Response Modes
• Remote Modbus TCP/RTU/ASCII

Ethernet Specifications


Network Protocols
ARP, BOOTP, DHCP, HTTP, ICMP, Ping, RARP, RFC 1006 (ISO over TCP), RFC 2217, SNMP (MIB-II), TCP/IP, Telnet, TFTP, and UDP socket services
Connector Type
RJ45F Auto MDI/MDI-X

Regulatory Approvals


Emissions
- FCC Part 15 Subpart B: Class A limit
– CLASS A LIMIT
– AS/NZS CISPR 22
– European Standard EN55022
– Canadian EMC Requirements
– ICES-003

Immunity EN55024
- IEC 1000-4-2/EN61000-4-2: ESD
– IEC 1000-4-3/EN61000-4-3: RF
– IEC 1000-4-4/EN61000-4-4: Fast Transient
– IEC 1000-4-5/EN61000-4-5: Surge
– IEC 1000-4-6/EN61000-4-6: Conducted Disturbance
– IEC 1000-4-8/EN61000-4-8: Magnetic Field
– IEC 1000-4-11/EN61000-4-11: Dips and Voltage Variations

Safety
- IEC 60950/EN60950 (LISTED)
– CSA C22.2 No. 60950/UL60950 Third Edition

Other Regulatory Approvals
– European Standard: RoHS2 Compliant under CE
– NEMA TS2 COMPLIANT

SOLUTIONS