DeviceMaster UP DB9M 2-Port 2E Modbus

Key Features:

The DeviceMaster UP DB9M 2 Port 2E Modbus is an industrial Ethernet Gateway designed to provide connectivity between a vast array of Modbus controllers and devices.
This gateway is quickly to setup and easy to use even with complex Modbus installation as it has a simplified configuration pages innovative functionality and informative diagnostic information.
• DIN-rail mounting and screw terminal power connections
• Highly flexible and unique Modbus functionality
• Multiple Modbus master and slave types
• Raw/ASCII Serial and Ethernet device support
• Variable power input eliminates need for power converters
• Dual Ethernet ports for daisy chaining network
connections between multiple units (2E model)
• PortVision® DX monitoring and management

Product Details

Hardware


Bus Interface Specification 10/100BASE-T
Memory
– SDRAM 8MB
– Flash 4MB
Enclosure UL94-V0 PLASTIC
Installation Method DIN Rail (35mm)
LED Indicators ETHERNET ACTIVITY, ETHERNET LINK, and STATUS
Dimensions
– 4.6″ x 3.9″ x 1.8″
– 11.68 x 9.9 x 4.57 cm
Product Weight
- 6.5 oz
– 184.27 g

Electrical Specifications


  • DC Input Voltage6-30V
  • Device
    • Current Consumption +24VDC85 mA
    • Power Consumption (maximum)0 W
  • Power Input RedundancyDual Redundant Power Input
  • ESD Surge ProtectionProvided minimum of 25KV protection for all serial lines. All Ethernet components are rated to 1.5KV magnetic surge protection.

Environmental Specifications


  • Air temperature
    • System On-37 to 74° C
    • System Off-40 to 85° C
  • Operating Humidity (non-condensing)5% to 95%
  • Altitude0 to 10,000 Feet
    3,048 m
  • Heat Output8 BTU/Hr
  • MTBF (Mean Time Between Failures)5 Years

Serial Communications


  • Connector TypeDB9 Male
  • Number of Ports2
  • Software InterfacesRS-232
    RS-422
    RS-485 2-Wire
    RS-485 4-Wire (Master/Slave)
  • Baud Rate300 to 230.4Kbps
    • Receive Buffer1024bytes
    • Transmit Buffer256bytes
  • Device Driver Data Control
    • Data Bits7 or 8
    • Parityodd, even, or none
    • Stop Bits1 or 2
    • Flow ControlHardware or Software

Communication Modes


  • Modbus TCP/RTU/ASCII to raw/ASCII Serial or Ethernet TCP/IP
  • Modbus/TCP to Modbus RTU/ASCII
  • Modbus RTU/ASCII (Auto Locate and Auto Route)
  • Raw/ASCII Data Stream and Command/Response Modes
  • Remote Modbus TCP/RTU/ASCII

Ethernet Specifications


  • Network ProtocolsARP, BOOTP, DHCP, HTTP, ICMP, Ping, RARP, RFC 1006 (ISO over TCP), RFC 2217, SNMP (MIB-II), TCP/IP, Telnet, TFTP, and UDP socket services
  • Connector TypeRJ45F Auto MDI/MDI-X
  • Schedule B Number80.1000

Regulatory Approvals


  • EmissionsFCC Part 15 Subpart B: Class A limit
    AS/NZS CISPR-22
    European Standard EN55022
    Canadian EMC requirements
    ICES-003
  • ImmunityEuropean Standard EN55024
    IEC 1000-4-2/EN61000-4-2: ESD
    IEC 1000-4-3/EN61000-4-3: RF
    IEC 1000-4-4/EN61000-4-4: Fast Transient
    IEC 1000-4-5/EN61000-4-5: Surge
    IEC 1000-4-6/EN61000-4-6: Conducted Disturbance
    IEC 1000-4-8/EN61000-4-8: Magnetic Field
    IEC 1000-4-11/EN61000-4-11: Dips and Voltage Variations
  • SafetyIEC 60950/EN60950 (RECOGNIZED)
    CSA C22.2 No. 60950/UL60950 Third Edition
  • Other Regulatory ApprovalsEuropean Standard: RoHS2 Compliant under CE
    NEMA TS2 COMPLIANT