Gigabit Ethernet Switch 10 Port

Key Features:

Gigabit Ethernet Industrial Switch 10 Port with Railway and Power Substation Certification

An Ethernet Industrial switch designed to be used in applications of rail traffic and power substations.
As this switch supports PoE it eliminates the need to install data and power cable which reduce the installation cost, In addition it made placing the switch in extreme surrounding condition possible.
• Railway approval according to EN50121-4:2006 and EN50125- 3:2003
• Power Substation approval according to IEC61850-3 and IEEE1613
• Fault tolerant fiber ring with reconfiguration < 20 ms
• Extensive features such as VLAN, QoS, IGMP-Snooping, STP/RSTP etc.
• Flexibility through SFP version with dual speed 100/1000 Mbps
• Power-over-Ethernet version
• Redundant power supply possible
• Operating temperature range -40..+75 °C
• Power supplies with railway approval with 24 VDC and 48 VDC / 60 W available

Product Details

General


Type Gigabit Ethernet Switch Layer 2+, IEEE 802.3 compliant
Performance Store-and-forward, Full wire-speed, non-blocking on all ports
MAC-Adresses 8,192 addresses, automatic learning and aging
VLANs Tagging IEEE 802.3ac
Priorisation IEEE 802.1p
VLAN IDs 0..4095
Static and dynamic VLAN table
Quality of Service 4 hardware-queues per port prioritisation according to:
* IPv4/IPv6
* VLAN priority IEEE 802.1p
* port
queue weighting strict or weighted, configurable”
Management CLI: telnet
Web: http
SNMPv1, SNMPv2c
Microsens NMP-Software

Local Ports (Twisted-Pair)


Number of Ports 8
Type 1x Gigabit Ethernet, triple speed
10/100/1000Base-T
7 x Fast Ethernet, dual speed 10/100Base-TX
Connector RJ-45 jack, shielded
Cable Type Twisted-Pair cable, category 5e, impedance 100 Ohm, length max. 100 m
Flow Control Pause frames (IEEE 802.3x), configurable
Pinout Auto MDI/MDI-X, auto polarity
Power-over-Ethernet Power Sourcing Equipment (PSE) IEEE 802.3af class 0, max. 15.4 W, forced-mode
(legacy-devices), pinout wires 1/2 (+), 3/6 (-)
(MS650869PM-48-B only)

Uplink (Pluggable Transceiver)


Number of Ports 3
Type Fast/Gigabit Ethernet, 100/1000Base-X
Connector SFP-Slot
Flow Control Pause frames (IEEE 802.3x), configurable

Uplink (Twisted-Pair)


Number of Ports 1
Type Gigabit Ethernet, triple speed
10/100/1000Base-T
Combo-Port (3rd SFP-Port)
Connector RJ-45 jack, shielded
Cable Type Twisted-Pair cable, category 5e, impedance 100 Ohm, length max. 100 m
Flow Control Pause frames (IEEE 802.3x), configurable
Pinout Auto MDI/MDI-X, auto polarity
Power-over-Ethernet Powered Device (PSE)
IEEE 802.3af class 0, max. 15.4 W, forced-mode (legacy-devices), pinout wires 1/2 (+), 3/6 (-)

Display


Power P1 Green: Main Power Supply active
Orange: Main Power Supply missing
P2 Green: Backup Power Supply active
Orange: Backup Power Supply missing
Link Port 1-8 Link (on) and activity (flashing) of the TP ports
Port 9-10 Link (on) and activity (flashing) of the fiber ports
Status G1 Green: Copper port 1 with Gigabit Ethernet speed
Orange: Third SFP fiber port active, copper port 1 without function (optional)
Ring: Switch configured for ring mode
RM: Ring Master (only in ring mode)
Alarm: Fiber link interrupted or Power Supply problem

Power Supply (DC)


Input Voltage 2x 48 VDC (redundant ports)
Power Consumption 8 W (typ.)
Fuse 1 A
Connector screw terminals

Environment


Operating Temperature -40°C..70°C
Storage Temperature -40°..85°C
Relative Humidity 5% to 90% non condensing

Mechanical


Dimensions 50 mm x 108 mm x 116 mm (w x d x h)
Weight 955 g (MS650869M-B)
743 g (MS650869PM-48-B)
Mounting DIN rail
Protection class IP 30

Standards Compliance


IEEE (Ethernet) 802.3i 10Base-T
802.3u 100Base-T
802.3z 1000Base-X
802.3ab 1000Base-T
802.3x Flow Control
802.3ac VLAN Tagging
802.3af PoE (MS MS650869PM-48-B, only)
802.1D Spanning Tree
802.1Q Tagged VLANs
802.1p Packet Prioritisation
802.1w Rapid Spanning Tree
802.1X Network Access Control
Other EN 50121-4:2006 (railway applications – electromagnetic compatibility)
EN 50125-3:2003 (railway applications – environmental conditions)
IEC 61850-3 (electrical substation automation)
IEEE 1613 (electric power substations)

RFC

IPv4:
– RFC 791 (IPv4)
– RFC 826 (ARP)
– RFC 792 (ICMP)
– RFC 2131 (DHCP)
– RFC 2474/3260 (IPv4 DiffServ/IPv6 Traffic Class)
– RFC 4541 (IGMP)

– RFC 1769 (SNTP)
– RFC 1155/1156/1157 (SNMPv1)
– RFC 1901/1905/1906 (SNMPv2)
– RFC 3411/3412/3584 (SNMPv3)
– RFC 2574/3414 (USM)
– RFC 2575/3415 (VACM)
– RFC 2865 (RADIUS)
– RFC 2866 (Accounting)
– RFC 2868 (Tunnel Attributes)
– RFC 5424 (Syslog)

Additional Features


Software - MICROSENS Ring-Protocol
– Port Monitor
– CDP v1, v2

Reliability


MTBF 400,000 h
Method calculated, MIL-HDBK-217F

 

SOLUTIONS