XGP5901B Series

Key Features:

Industrial M2M Cellular Protocol Gateway

 

• Supports Modbus TCP/RTU/ASCII, DNP3, IEC61850,
• IEC60870-5-101/104, and Ethernet/Serial in client/server master/slave modes.
• GPRS/3G/4G Cellular Protocol Gateway with extensive LTE Band support, including:
– EU Model: 2100/1800/850/2600/900/800MHz (B1/B3/B5/B7/B8/B20)
– US Model: 1900/AWS/850/700/700/1900MHz (B2/B4/B5/B13/B17/B25)
• Industrial-grade hardware for operating in harsh environments
• 1 x 10/100/1000Mbps Ethernet port
• 1 x RS-232/485 port – baud rate up to 921.6 Kbps
• 2 x High speed USB 2.0 ports
• Management via SMS, Web Browser and Windows Utility
• VPN over PPTP, IPSec or OpenVPN for secure communica

Product Details

Protocol Specification

IEC61850 Server/ Client
Supported Functions · Generic access to the data (Read, Write)

· 8 Logical Devices per Port

· GOOSE (Generic Object Oriented Substation Event)
– a GOOSE message will be generated by the gateway automatically upon event(*)

· (*)Being other protocols not Real-Time, there is no guarantee that GOOSE message is generated within 1 ms from the event itelf.

Supported Control Type of commands · Direct-with-Normal-Security Select Before Operate (SBO)-with-Normal-Security

· Direct-with-Enhanced Security Select Before Operate (SBO)-with-Enhanced-Security

Implemented Protocol Subsets · IEC 61850-6 (Substation Configuration Language Description: SCL)

· IEC 61850-7-1 (Principles and Models)

· IEC 61850-7-2 (Abstract Communication Service

· Interface: ACSI

· IEC 61850-7-3 (Common Data Classes: CDC)

· IEC 61850-7-4 (Logical Nodes and data Object Classes)

· IEC 61850-8-1 (Mapping to Manufacturing Message Specification: MMS)

· Edition 1 & Edition 2 are both Supported

DNP3 Server/ Client/ Master/ Slave
General Specifications · Serial Mode or Ethernet with TCP or UDP Mode

· Server side supports serving up to 5 client in TCP Mode

· Client side in a single RS-485 port, supports connecting up to 16 IEDs

· Client side supports connecting up to 16 IEDs

· Maximum Fragment size 2048 octets

· Protocol implementation with configurable parameters conforms to IEEE Std 1815-2012 level 2

Supported Functions · Time Synchronization generic access to the data(Read, Write)

· Commands with or without preselection (Select, Operate, Direct Operate)

· Transmission of time-tagged events

· Counter management (Immediate Freeze, Freeze and Clear)

· Self-address

Supported DNP3 Object Library · Binary Inputs up to 8000 pts

· Binary Outputs up to 2000 pts

· Double Inputs up to 4000 pts

· Analog Inputs up to 250 pts

· Analog Outputs up to 250 pts

· Counters up to 250 pts

Modbus Server/ Client/ Master/ Slave
General Specifications · Support Modbus RTU and ASCII in Serial mode

· Support Modbus in TCP mode

· For Modbus Client in TCP mode, support connecting up to 64 Modbus servers

· For Modbus Server in TCP mode, support serving up to 64 Modbus clients

· Support maximum number of data points in read direction: 8000 pts

· Support maximum number of commands in write direction: 4000 pts

Supported Function Codes 1: Read Coils
2: Read Discrete Inputs
3: Read Holding Registers
4: Read Input Registers
5: Write Single Coil
6: Write Single Register
15: Write Multiple Coils
16: Write Multiple Registers
43/14: Read Device Identification (server side only)
Supported Exception Codes 1: illegal function
2: illegal data address
3: illegal data value
4: server device failure
6: server device busy
IEC 60870-5-101 Master/ Slave
General Specifications · Protocol implementation with configurable parameters conforms to the IEC 60870-5-101 edition 2 specification

· Process Information in Monitor and Control Direction

· Balanced and Unbalanced Modes

· CP24Time2a or CP56Time2a timestamp for monitor direction report

Supported Functions · Station Initialization

· Interrogation

· Read Procedure

· Cyclic Data and Spontaneous Transmission (Slave Side only)

· Clock Synchronization

· Transmission of Integrated Totals

· Direct and SBO command

Supported Data Types · Monitors Points: Each supports up to 1000 pts: Single Point, Double Point, Step Position, Bit String, Measured with Normalized Value, Measured with Scaled Value, Measured Short Floating-Point Value, Integrated Totals

· Control Points: Each supports up to 500 pts: Single Command, Double Command, Regulating Step Command, Set Point Command with Normalized Value, Set Point Command with Scaled Value, Set Point Command Short Floating Point, Bit string

IEC 60870-5-103 Master/ Slave
General Specifications · Protocol implementation with configurable parameters conforms to the IEC 60870-5-103:1997

· Master supports connecting up to 16 IEDs

· Process Information in Monitor and Control Direction

· Unbalanced Modes

Supported Functions · Station Initialization, Supports reset FCB and CU

· General Interrogation

· Clock Synchronization

· Command Transmission

· Test Mode

· Blocking of Monitor Direction

Supported Information · Monitor direction:

– Status indications in monitor direction: from <16> to <30>

– Supervision indications in monitor direction: <32>, <33>, from <35> to < 39>, <46>, <47>

– Earth fault indications in monitor direction: from <48> to <52>

 Fault indications in monitor direction: from <64> to <93>

– Auto-reclosure indications in monitor direction: from <128> to <130>

– Measurands in monitor direction: from <144> to <148>

· Control direction:
– General commands in control direction: from <16> to <19>, from <23> to <26>

IEC 60870-5-104 Server/ Client
General Specifications · Server side supports serving up to 5 client

· Client side supports connecting up to 10 IEDs

· Protocol implementation with configurable parameters conforms to the IEC 60870-5-104 specification edition 2

· Process Information in Monitor and Control Direction

· CP56Time2a timestamp for Control Commands

Supported Functions · Station Initialization

· Interrogation

· Read Procedure (Server side only)

· Cyclic Data and Spontaneous Transmission (Server side only)

· Clock Synchronization

· Transmission of Integrated Totals

· Direct and SBO command

Supported Data Types · Monitors Points:Each supports maximum 1000 pts: Single Point, Double Point, Step Position, Bit String, Measured with Normalized Value, Measured with Scaled Value, Measured Short Floating Points Value, Integrated Totals.

· Control Points: Each supports maximum 500 pts: Single Command, Double Command, Regulating Step Command, Set Point Command with Normalized Value, Set Point Command with Scaled Value, Set Point Command Short Floating Point, Bitstring.

· Event Logging (Server Side only) Universal Event Buffer up to 20,000 Events

TECHNICAL SPECIFICATIONS

 

Specifications
Standard GSM/ GPRS/ EDGE/ UMTS/ HSPA+/ SCDMA/ LTE
Band Options EU version:

–  FDD LTE: 2100/1800/850/2600/900/800MHz(B1/B3/B5/B7/B8/B20)

–  TDD LTE: 2600/2300/2500MHz(B38/B40/B41)

–  WCDMA: 2100/850/900MHz (B1/B5/B8)

–  GSM: 900/1800

US version:

–  UMTS: 1900/1700/850/700/700bMHz(B2/B4/B5/B12/B17)

–  WCDMA: 1900/1700/850MHz (B2/B4/B5)

–  GSM: 850/1900MHz

Maximum 4G throughput EU version:

–  LTE-FDD Max 150Mbps (DOWNLINK), Max 50Mbps (UPLINK)

–  LTE-TDD Max 130Mbps (DOWNLINK), Max 35Mbps (UPLINK)

–  DC-HSPA+ Max 42Mbps (DOWNLINK), Max 5.76Mbps(UPLINK)

–  UMTS Max 384Kbps(DOWNLINK), Max 384Kbps(UPLINK)

–  TD-SCDMA Max 4.2Mbps (DOWNLINK), Max 2.2Mbps  (UPLINK)

–  EDGE Max.236.8 Kbps (DOWNLINK), Max.236.8 Kbps (UPLINK)

–  GPRS Max.85.6 Kbps (DOWNLINK), Max 85.6 Kbps (UPLINK)

US version:

–  LTE-FDD Max 100Mbps (DOWNLINK), Max 50Mbps (UPLINK)

–  LTE-TDD Max 61Mbps (DOWNLINK) Max 18Mbps (UPLINK)

–  DC-HSPA+ Max 42Mbps (DOWNLINK) Max 5.76Mbps(UPLINK)

–  UMTS Max 384Kbps(DOWNLINK) Max 384Kbps(UPLINK)

–  TD-SCDMA Max 4.2Mbps(DOWNLINK) Max 2.2Mbps(UPLINK)

–  EDGE Max.236.8 Kbps (DOWNLINK)/ Max.236.8 Kbps (UPLINK)

–  GPRS Max.85.6 Kbps (DOWNLINK)/ Max.85.6 Kbps (UPLINK)

Network Interface
Ethernet Port 1x 10/100/1000BASE-TX RJ-45
Compliance IEEE 802.3 10BASE-T

IEEE 802.3u for 100BASE-T(X)
IEEE 802.3ab for 1000BASE-T

Serial Interface
Connector 14-Pin 5.08mm Terminal Block (integrated with DI/DOs) or D-Sub9 connector
Port 1
Mode 1 port RS-232/485 (2-wire) software selectable
Baud Rate 1,200~921,600 bps
Parity None, Odd, Even
Data Bits 7, 8
Stop Bits 1, 2
USB Interface
Speed USB 2.0
Connector USB A Type *2
DI/DO Interface (IO model only)
DI 2 channels photo coupler isolated digital input
DO 2 channels digital output. N.O.( 2A@24VDC)
Internal Battery function (Battery model only)
Battery function Provide normal operation at least 10 seconds after power failure function
Power Characteristics
Connector 3-Pin 5.08mm Lockable Terminal Block
Input Voltage 9-48 VDC
Power Consumption 0.6A @ 12VDC
Power Redundancy USB DC 5V Power Input
Reverse Polarity Protection Yes
Mechanicals
Housing IP30 protection, metal housing
Dimensions (W x H x D) 32mm x 122mm x 92mm
Installation DIN-Rail or Wall-Mount (optional kit)
Reset Button Yes
Weight 400g
Environmental Limits
Operating Temperature -40°C ~ 70°C (-40°F ~ 158°F)
Storage Temperature -40°C ~ 85°C (-40°F ~ 185°F)
Ambient Relative Humidity 5 ~ 95% RH, (non-condensing)
Software
Protocols ARP, IPv4, ICMP, TCP, UDP, DHCP Client, NTP Client, SNMPv1/v2c/v3, HTTP, HTTPS,

RFC2217, RSTP, and SMTP/TLS

Additional features Remote SMS monitoring
Security VPN through IPsec tunneling (max 10 tunnels), OpenVPN, and PPTP on cellular or LAN
Network NAT

REGULATORY APPROVALS

 

Regulatory Approvals
Safety EN 60950-1, UL60950-1, IEC60950-1
EMC FCC Part 15, Subpart B, Class A

EN301489-19, EN301489-52, EN301908-1, EN303413, EN 55024, EN 55032, EN61000-6-4, EN 61000-3-2, EN 61000-3-3, EN61000-6-2

Test Item Value Level
IEC 61000-4-2 ESD Contact Discharge
Air Discharge
±8KV

±15KV

4

4

IEC 61000-4-3 RD 80-1000MHz 10 V/m 3
IEC 61000-4-4 EFT AC Power Port
Signal Port
±2.0KV

±2.0KV

3

4

IEC 61000-4-5  

Surge

AC Power Port
AC Power Port
Signal Port
Line-to Line±1.0KV
Line-to Earth±2.0KV
Line-to Earth±2.0KV
3

3

3

IEC 61000-4-6 CS 0.15-80MHz 10 Vrms 3
IEC 61000-4-8 PFMF Enclosure 10 A/m 3
 

IEC 61000-4-11

 

DIP

 

AC Power Port

1.      >95%,Reduction,0.5period

2.      30%, Reduction,25 period

>95%,Reduction,250 period

 

Shock MIL-STD-810G Method 516.7
Drop MIL-STD-810G Method 516.7
Vibration MIL-STD-810G Method 514.7
RoHS Yes
MTBF 20.88 years according to MIL-HDBK-217F (Model average)
Warranty 5 years