IEC61850 Server/ Client | |
Supported Functions | · Generic access to the data (Read, Write)
· 8 Logical Devices per Port · GOOSE (Generic Object Oriented Substation Event) · (*)Being other protocols not Real-Time, there is no guarantee that GOOSE message is generated within 1 ms from the event itelf. |
Supported Control Type of commands | · Direct-with-Normal-Security Select Before Operate (SBO)-with-Normal-Security
· Direct-with-Enhanced Security Select Before Operate (SBO)-with-Enhanced-Security |
Implemented Protocol Subsets | · IEC 61850-6 (Substation Configuration Language Description: SCL)
· IEC 61850-7-1 (Principles and Models) · IEC 61850-7-2 (Abstract Communication Service · Interface: ACSI · IEC 61850-7-3 (Common Data Classes: CDC) · IEC 61850-7-4 (Logical Nodes and data Object Classes) · IEC 61850-8-1 (Mapping to Manufacturing Message Specification: MMS) · Edition 1 & Edition 2 are both Supported |
DNP3 Server/ Client/ Master/ Slave | |
General Specifications | · Serial Mode or Ethernet with TCP or UDP Mode
· Server side supports serving up to 5 client in TCP Mode · Client side in a single RS-485 port, supports connecting up to 16 IEDs · Client side supports connecting up to 16 IEDs · Maximum Fragment size 2048 octets · Protocol implementation with configurable parameters conforms to IEEE Std 1815-2012 level 2 |
Supported Functions | · Time Synchronization generic access to the data(Read, Write)
· Commands with or without preselection (Select, Operate, Direct Operate) · Transmission of time-tagged events · Counter management (Immediate Freeze, Freeze and Clear) · Self-address |
Supported DNP3 Object Library | · Binary Inputs up to 8000 pts
· Binary Outputs up to 2000 pts · Double Inputs up to 4000 pts · Analog Inputs up to 250 pts · Analog Outputs up to 250 pts · Counters up to 250 pts |
Modbus Server/ Client/ Master/ Slave | |
General Specifications | · Support Modbus RTU and ASCII in Serial mode
· Support Modbus in TCP mode · For Modbus Client in TCP mode, support connecting up to 64 Modbus servers · For Modbus Server in TCP mode, support serving up to 64 Modbus clients · Support maximum number of data points in read direction: 8000 pts · Support maximum number of commands in write direction: 4000 pts |
Supported Function Codes | 1: Read Coils 2: Read Discrete Inputs 3: Read Holding Registers 4: Read Input Registers 5: Write Single Coil 6: Write Single Register 15: Write Multiple Coils 16: Write Multiple Registers 43/14: Read Device Identification (server side only) |
Supported Exception Codes | 1: illegal function 2: illegal data address 3: illegal data value 4: server device failure 6: server device busy |
IEC 60870-5-101 Master/ Slave | |
General Specifications | · Protocol implementation with configurable parameters conforms to the IEC 60870-5-101 edition 2 specification
· Process Information in Monitor and Control Direction · Balanced and Unbalanced Modes · CP24Time2a or CP56Time2a timestamp for monitor direction report |
Supported Functions | · Station Initialization
· Interrogation · Read Procedure · Cyclic Data and Spontaneous Transmission (Slave Side only) · Clock Synchronization · Transmission of Integrated Totals · Direct and SBO command |
Supported Data Types | · Monitors Points: Each supports up to 1000 pts: Single Point, Double Point, Step Position, Bit String, Measured with Normalized Value, Measured with Scaled Value, Measured Short Floating-Point Value, Integrated Totals
· Control Points: Each supports up to 500 pts: Single Command, Double Command, Regulating Step Command, Set Point Command with Normalized Value, Set Point Command with Scaled Value, Set Point Command Short Floating Point, Bit string |
IEC 60870-5-103 Master/ Slave | |
General Specifications | · Protocol implementation with configurable parameters conforms to the IEC 60870-5-103:1997
· Master supports connecting up to 16 IEDs · Process Information in Monitor and Control Direction · Unbalanced Modes |
Supported Functions | · Station Initialization, Supports reset FCB and CU
· General Interrogation · Clock Synchronization · Command Transmission · Test Mode · Blocking of Monitor Direction |
Supported Information | · Monitor direction:
– Status indications in monitor direction: from <16> to <30> – Supervision indications in monitor direction: <32>, <33>, from <35> to < 39>, <46>, <47> – Earth fault indications in monitor direction: from <48> to <52> – Fault indications in monitor direction: from <64> to <93> – Auto-reclosure indications in monitor direction: from <128> to <130> – Measurands in monitor direction: from <144> to <148> · Control direction: |
IEC 60870-5-104 Server/ Client | |
General Specifications | · Server side supports serving up to 5 client
· Client side supports connecting up to 10 IEDs · Protocol implementation with configurable parameters conforms to the IEC 60870-5-104 specification edition 2 · Process Information in Monitor and Control Direction · CP56Time2a timestamp for Control Commands |
Supported Functions | · Station Initialization
· Interrogation · Read Procedure (Server side only) · Cyclic Data and Spontaneous Transmission (Server side only) · Clock Synchronization · Transmission of Integrated Totals · Direct and SBO command |
Supported Data Types | · Monitors Points:Each supports maximum 1000 pts: Single Point, Double Point, Step Position, Bit String, Measured with Normalized Value, Measured with Scaled Value, Measured Short Floating Points Value, Integrated Totals.
· Control Points: Each supports maximum 500 pts: Single Command, Double Command, Regulating Step Command, Set Point Command with Normalized Value, Set Point Command with Scaled Value, Set Point Command Short Floating Point, Bitstring. · Event Logging (Server Side only) Universal Event Buffer up to 20,000 Events |
Specifications | ||||
Standard | GSM/ GPRS/ EDGE/ UMTS/ HSPA+/ SCDMA/ LTE | |||
Band Options | EU version:
– FDD LTE: 2100/1800/850/2600/900/800MHz(B1/B3/B5/B7/B8/B20) – TDD LTE: 2600/2300/2500MHz(B38/B40/B41) – WCDMA: 2100/850/900MHz (B1/B5/B8) – GSM: 900/1800 US version: – UMTS: 1900/1700/850/700/700bMHz(B2/B4/B5/B12/B17) – WCDMA: 1900/1700/850MHz (B2/B4/B5) – GSM: 850/1900MHz |
|||
Maximum 4G throughput | EU version:
– LTE-FDD Max 150Mbps (DOWNLINK), Max 50Mbps (UPLINK) – LTE-TDD Max 130Mbps (DOWNLINK), Max 35Mbps (UPLINK) – DC-HSPA+ Max 42Mbps (DOWNLINK), Max 5.76Mbps(UPLINK) – UMTS Max 384Kbps(DOWNLINK), Max 384Kbps(UPLINK) – TD-SCDMA Max 4.2Mbps (DOWNLINK), Max 2.2Mbps (UPLINK) – EDGE Max.236.8 Kbps (DOWNLINK), Max.236.8 Kbps (UPLINK) – GPRS Max.85.6 Kbps (DOWNLINK), Max 85.6 Kbps (UPLINK) US version: – LTE-FDD Max 100Mbps (DOWNLINK), Max 50Mbps (UPLINK) – LTE-TDD Max 61Mbps (DOWNLINK) Max 18Mbps (UPLINK) – DC-HSPA+ Max 42Mbps (DOWNLINK) Max 5.76Mbps(UPLINK) – UMTS Max 384Kbps(DOWNLINK) Max 384Kbps(UPLINK) – TD-SCDMA Max 4.2Mbps(DOWNLINK) Max 2.2Mbps(UPLINK) – EDGE Max.236.8 Kbps (DOWNLINK)/ Max.236.8 Kbps (UPLINK) – GPRS Max.85.6 Kbps (DOWNLINK)/ Max.85.6 Kbps (UPLINK) |
|||
Network Interface | ||||
Ethernet Port | 1x 10/100/1000BASE-TX RJ-45 | |||
Compliance | IEEE 802.3 10BASE-T
IEEE 802.3u for 100BASE-T(X) |
|||
Serial Interface | ||||
Connector | 14-Pin 5.08mm Terminal Block (integrated with DI/DOs) or D-Sub9 connector | |||
Port | 1 | |||
Mode | 1 port RS-232/485 (2-wire) software selectable | |||
Baud Rate | 1,200~921,600 bps | |||
Parity | None, Odd, Even | |||
Data Bits | 7, 8 | |||
Stop Bits | 1, 2 | |||
USB Interface | ||||
Speed | USB 2.0 | |||
Connector | USB A Type *2 | |||
DI/DO Interface (IO model only) | ||||
DI | 2 channels photo coupler isolated digital input | |||
DO | 2 channels digital output. N.O.( 2A@24VDC) | |||
Internal Battery function (Battery model only) | ||||
Battery function | Provide normal operation at least 10 seconds after power failure function | |||
Power Characteristics | ||||
Connector | 3-Pin 5.08mm Lockable Terminal Block | |||
Input Voltage | 9-48 VDC | |||
Power Consumption | 0.6A @ 12VDC | |||
Power Redundancy | USB DC 5V Power Input | |||
Reverse Polarity Protection | Yes | |||
Mechanicals | ||||
Housing | IP30 protection, metal housing | |||
Dimensions (W x H x D) | 32mm x 122mm x 92mm | |||
Installation | DIN-Rail or Wall-Mount (optional kit) | |||
Reset Button | Yes | |||
Weight | 400g | |||
Environmental Limits | ||||
Operating Temperature | -40°C ~ 70°C (-40°F ~ 158°F) | |||
Storage Temperature | -40°C ~ 85°C (-40°F ~ 185°F) | |||
Ambient Relative Humidity | 5 ~ 95% RH, (non-condensing) | |||
Software | ||||
Protocols | ARP, IPv4, ICMP, TCP, UDP, DHCP Client, NTP Client, SNMPv1/v2c/v3, HTTP, HTTPS,
RFC2217, RSTP, and SMTP/TLS |
|||
Additional features | Remote SMS monitoring | |||
Security | VPN through IPsec tunneling (max 10 tunnels), OpenVPN, and PPTP on cellular or LAN | |||
Network | NAT |
Regulatory Approvals | ||||
Safety | EN 60950-1, UL60950-1, IEC60950-1 | |||
EMC | FCC Part 15, Subpart B, Class A
EN301489-19, EN301489-52, EN301908-1, EN303413, EN 55024, EN 55032, EN61000-6-4, EN 61000-3-2, EN 61000-3-3, EN61000-6-2 |
|||
Test | Item | Value | Level | |
IEC 61000-4-2 | ESD | Contact Discharge Air Discharge |
±8KV
±15KV |
4
4 |
IEC 61000-4-3 | RD | 80-1000MHz | 10 V/m | 3 |
IEC 61000-4-4 | EFT | AC Power Port Signal Port |
±2.0KV
±2.0KV |
3
4 |
IEC 61000-4-5 |
Surge |
AC Power Port AC Power Port Signal Port |
Line-to Line±1.0KV Line-to Earth±2.0KV Line-to Earth±2.0KV |
3
3 3 |
IEC 61000-4-6 | CS | 0.15-80MHz | 10 Vrms | 3 |
IEC 61000-4-8 | PFMF | Enclosure | 10 A/m | 3 |
IEC 61000-4-11 |
DIP |
AC Power Port |
1. >95%,Reduction,0.5period
2. 30%, Reduction,25 period >95%,Reduction,250 period |
- |
Shock | MIL-STD-810G Method 516.7 | |||
Drop | MIL-STD-810G Method 516.7 | |||
Vibration | MIL-STD-810G Method 514.7 | |||
RoHS | Yes | |||
MTBF | 20.88 years according to MIL-HDBK-217F (Model average) | |||
Warranty | 5 years |