• UL Listed 1863 (Communications-Circuit Accessories), CE • Operating temperature: -40°C to 75°C • Storage/transport temperature: -40°C to 80°C • Relative humidity (non-condensing): 10% to 95% • Insertion Loss: ≤.3dB (Multimode), ≤.2dB (Singlemode) • Plug/Unplug Durability: 1000 times |
Mechanical Construction |
---|
– Dimensions with adapters installed: (H x D x W) 7.75” x 5.75” x 3.5” – Mounting Options: Rear DIN-Rail, Side DIN-Rail or surface mount – Weight: 2.3lbs. – Protection class: IP20 |
Materials of Construction |
---|
– Patch panel body and faceplate: 18 gauge powder-coat painted steel – Fiber optic adapters: UL 90 V-0 Thermoplastic – Cable Glands: Plastic with max. cable diameter of 12mm (14mm max. also available) |
Warranty |
---|
Lifetime warranty on materials and workmanship. |
Scope of Delivery |
---|
Patch panel, DIN-Rail mounting adapter, 2ea. cable glands. |