Input voltage range AC input: 85 – 264 VAC universal input DC input: 90 – 280 VDC (external fuse or circuit breaker required) Input voltage frequency 45 – 65 Hz Harmonic limits EN 61000-3-2, Class A (for limited output power) Holdup time 85 VAC 20 ms typ. 184 VAC 20 ms typ. Inrush current 115 VAC < 15 A 230 VAC < 30 A Standby Power (external ON/OFF activated) 250 W model: 3W 500 W model: 5W 750 W model: 7W Start-up delay 250 ms typ. Efficiency (at nominal load) 115 VAC 91.5 % typ. 230 VAC 93 % typ. |
Output voltage adj. range – 24 VDC models: 24 – 28,8 VDC (SELV voltage) – 48 VDC models: 48 – 60 VDC – 72 VDC models: 60 – 74 VDC Regulation – Input variation 0.5 % max. – Load variation (10–90 %) 1.0 % max. Ripple and Noise (20MHz bandwidth) < 100 mV pk-pk Electronic short circuit protection current limitation at Imax. constant current, automatic recovery Output overvoltage protection – 24 VDC models: < 35 V – 48 VDC models: < 70 V – 72 VDC models: < 100 V Overload protection electronic overload protection Over temperature protection switch off at overtemperature, automatic restart Power back immunity – 24 VDC models: 30 V Status indicator dual color LED (green: DC ok, red: DC off) Power OK signal – trigger threshold: – 24 VDC models: 21.5 – 22.5 V – 48 VDC models: TBD – 72 VDC models: TBD – active output signal: – 12 VDC models: 11.0 V ±1.0 V (reference to –Vout) TBD (20 mA max. for TSP 070, 40 mA max. for TSP 140) – 24 VDC models: 22.0 V ±2.0V / 20 mA max. – relay output DC OK = contact closed – rated: 30 VDC/1.0 A for 24 VDC models – rated: TBDfor 48 VDC model – rated: TBDfor 72 VDC models Max. capacitive load Temperature range – Operating –25°C to +70°C max. (optional –40ºC to +70ºC) – Storage –25°C to +85°C Power derating 3 %/K above 60ºC Humidity (non-condensing) 95 % rel. H max. Temperature coefficient 0.02 %/K Isolation according to IEC/EN 60950-1, UL 60950-1, UL 508 Safety standards – Information technology equipment IEC/EN 60950-1, UL 60950-1, CSA-C22.2 No. 60950-1-03 – Industrial control equipment UL 508, CSA-C22.2 No. 107 – Electrical equipment for machines EN 60204 – Electronic equipment for power installation EN 50178 – Safety transformers for SMPS EN 61558-2-4, EN 61558-2-4 – Control equipment for hazardous location UL 60079-15 (Class I, Division 2, Groups A,B,C,D AEx n C II C T4 U) IEC/EN60 079-15(Class I, Zone 2, EEx nC II C T4 U), ( II3G EEX nAC IIC T4 (T3 with limited power) Safety approvals and certifications – CB report for IEC/EN 60950-1 – UL approvals UL 60950-1 rec. File: e181381, UL 508C listed File: e210002 – CSA certification (file no. 219759) for UL 60950-1, UL 508, UL 60079-15-02, ANSI/ISA 12.12.01, CSA-22.2 No. 60950-1-03, CSA C22.2 No. 107, CSA 60079-15-02 – II3G ATEX 94/9/EC certificate no. EPS 12 ATEX 1 424 X (option -EX only) – IECEx test report for IEC 60079-15 – BG certification EN 60950-1, EN 60204-1, EN 61558-2-16, EN 50178 Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3 – Conducted RI suppression on input EN 55011 class B, EN 55022 class B, – Radiated RI suppression EN 55011 class B, EN 55022 class B, Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3 – Electrostatic discharge (ESD) IEC / EN 61000-4-2 4 kV / 8 kV criteria A – Radiated RF field immunity IEC / EN 61000-4-3 10 V / m criteria A – Electrical fast transient / burst immunity IEC / EN 61000-4-4 2 kV criteria B – Surge immunity IEC / EN 61000-4-5 1 kV / 2 kV criteria B – Immunity to conducted RF disturbances IEC / EN 61000-4-6 10 V criteria A – Power frequency field immunity IEC / EN 61000-4-8 30 A / m criteria A – Mains voltage dips and interruptions IEC / EN 61000-4-11 criteria B/C – Voltage sag immunity SEMI F47 |
– Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10 – 55 Hz, 2 g, 11 oct/min – Shock acc. IEC 60068-2-27 3 axis, 25 g half sine, 11 ms |