TIS Series

Key Features:

The TIS series is designed with a switching power to serve applications in industrial process control systems and with machine tools. With excellent specifications and high immunity against electrical disturbances the TIS series guarantees a reliable power supply for sensitive loads in rugged industrial environments.

• Universal battery controller module for uninterruptable 24 VDC and 48 VDC bus voltage
• Redundant inputs for two independent sources
• Battery protection for over voltage, deep discharge, short circuit and reverse connection
• Alarm outputs for input, output and battery condition
• Remote On/Off for battery and power supply
• Controlled end of charge voltage by temperature sensor
• International safety approval package
• 3-year product warranty

Product Details

Input Specifications


Input voltage  
– TIS 50: 93 – 264 VAC
– TIS 75, 150, 300, 600: 93 – 132 VAC / 187 – 264 VAC
– TIS 50 0 -124-230. 187 – 264 VAC
– TIS 500 -124-115: 93 – 132 VAC

Input frequency 47 – 63 Hz

Input current at full load (typ.) at 115 VAC at 230 VAC
– TIS 50: 0.85 A 0.50 A
– TIS 75: 1.3 A 0.75 A
– TIS 150: 2.7 A 1.6 A
– TIS 300: 4.9 A 2.9 A
– TIS 500: 6.0 A 4.3 A
– TIS 600: 7.0 A 5.0 A

Recommended circuit breaker, characteristic C or fuse, slow blow type
– TIS 50: 5.0 A
– TIS 75: 5.0 A
– TIS 150: 10.0 A
– TIS 300: 15.0 A
– TIS 500: 15.0 A
– TIS 600: 20.0 A

Output Specifications


Output voltage adj. range
– 12 VDC models: 12 – 14 VDC
– 24 VDC models: 24 – 28 VDC
– 48 VDC models: 48 – 52 VDC
– 72 VDC models: 60 – 76 VDC

Regulation
– Input variation 0.2 %
– Load variation (10–90%) TIS 50, TIS 75, TIS 150: 1.0 %
– TIS 300, TIS 500, TIS 600: 0.3 %
(2.0 % in parallel operation)

Ripple and noise(20MHz bandwidth)  <50 mV pk-pk

Electronic short circuit protection
– Current limitation at 110 % typ. (constant current, automatic restart)

Over voltage protection, trigger point at  140 % typ. Vout nom.
– Hold-up time ( 115 VAC ,230 VAC)
– TIS 50 … TIS 300: min. 25 ms min. 30 ms
– TIS 500: min. 20 ms min. 40 ms
– TIS 600: min. 15 ms min. 25 ms

General Specifications


Operating temperature 

– Normal Mode : –25°C to +70°C max. (without derating)
– Buffer Mode nominal 24 VDC mode: derating above +50°C : 2.0 %/K 48 VDC mode: derating above +40°C : 2.0 %/K
– Buffer Mode boost 24 VDC mode: up to +40°C for 10 minutes max. 48 VDC mode: up to +40°C for 3 minutes max. .

Temperature coefficient  0.02 %/K

Humidity(non-condensing)  95 % rel. H max.

Safety standards
– IEC/EN 60950-1 (SELV, except 72 VDC models)
– UL/cUL 60950-1, UL 508, UL/cUL 1604

Safety approvals
– CB report for IEC 60950
– UL approvals UL/cUL 60950, Fil e e181381
• UL/cUL 508, File e210002
• UL/cUL 1604, Fil e e213613 not for TIS 50 & 500
• (Class I, Div. 2, Groups A, B, C and D hazardous locations)
– CSA certificate (UL 60950-1, CSA 60950-1)

Electromagnetic compatibility (EMC), Emissions
– Conducted RI suppression on input EN 55011 class B, EN 55022 class B,
FCC part 15, level B
– Radiated RI suppression EN 55011 class A, EN 55022 class A,
FCC part 15, level A

Electromagnetic compatibility (EMC), Immunity EN 61000-6-2
– Electrostatic discharge (ESD) IEC/EN 61000-4-2 4 kV/8 kV
– Radiated RF field immunity IEC/EN 61000-4-3 10 V/m
– Electrical fast transient / burst immunity IEC/EN 61000-4-4 2 kV
– Surge immunity IEC/EN 61000-4-5 2 kV/4 kV
– Immunity to conducted RF disturbances IEC/EN 61000-4-6 10 V
– Power frequency field immunity IEC/EN 61000-4-8 30 A/m

Environment
– Vibration IEC 60068-2-6; 1 gn, 200 sweeps, each axis
– Shock IEC 60068-2-27; 15 gn, 11 ms, each axis

SOLUTIONS