Input voltage range – TSP 070/090 85 – 264 VAC universal input – other models: 85 – 132 / 187 – 264 VAC autoselect – output current derating at operation below 100 VAC see graph B, page 4 Input voltage frequency 47 – 63 Hz Harmonic limits EN 61000-3-2, Class A (for limited output power) Holdup time – 230 VAC 20 ms – 115 VAC 10 msat full load,20 msat 66% load Inrush current (115 VAC 230 VAC) – TSP 070/090 < 12 A < 20 A – TSP 140/180 < 13 A < 25 A – TSP 360 < 16 A < 25 A – TSP 600 < 25 A < 30 A Recommended circuit breaker, – TSP 070/090/140/180 6.0 – 16.0 A characteristic B – TSP 360 10.0 – 16.0 A – TSP 600 16.0 – 25.0 A Efficiency 87 % typ. |
Output voltage adj. range – 12 VDC models: 12 – 14 VDC – 24 VDC models: 24 – 28 VDC – 36 VDC model: 36 – 42 VDC – 48 VDC models: 48 – 56 VDC Regulation – Input variation 0.5 % max. – Load variation (10–100 %) 0.5 % max. Ripple and Noise (20MHz bandwidth) – 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Electronic short circuit protection current limitation at Imax. constant current, automatic recovery Output overvoltage protection – 12 VDC models: 20 V – 24 VDC models: 35 V – 36 VDC model: 43 V – 48 VDC models: 60 V Overload protection – electronic overload protection Over temperature protection – switch off at over temperature, automatic restart Power back immunity – 12 VDC models: 16 V – 24 VDC models: 35 V – 36 VDC model: 48 V – 48 VDC models: 63 V Power OK signal – trigger threshold: – 12 VDC models: 9 – 11 V – 24 VDC models: 18 – 22 V – 36 VDC model: 27 – 34 V – 48 VDC models: 36 – 46 V – active output signal: – 12 VDC models: 11.0 V ±1.0 V (reference to –Vout) (20 mA max. for TSP 070, 40 mA max. for TSP 140) – 24 VDC models: 22.0 V ±2.0V / 20 mA max. (10 mA max. for TSP 090, 20mA max. for others) – 36 VDC model: 34.0 V ±2.0 V / 20 mA max. – 48 VDC models: 44.0 V ±4.0 V / 15 mA max. – relay output DC OK = contact closed – rated: 30 VDC/1.0 A for 12/24 VDC models – rated: 30 VDC/2.0 A for 36 VDC model – rated: 48 VDC/0.5 A for 48 VDC models Max. capacitive load unlimited Temperature range – Operating –25°C to +70°C max. Cooling convection cooling, no internal fan Humidity (non-condensing) 95 % rel. H max. – Remote On/Off by ext. contact. – DC on: -S contact open – DC off: -S connectetd via 1Kohm to -Vout Isolation according to IEC/EN 60950-1, UL 60950-1, UL 508 Safety standards – Information technology equipment IEC/EN 60950-1, UL 60950-1, CSA-C22.2 No. 60950-1-03 – Industrial control equipment UL 508, CSA-C22.2 No. 107 – Electrical equipment for machines EN 60204 – Electronic equipment for power installation EN 50178 – Safety transformers for SMPS EN 61558-2-16 – Limited power source (model TSP 090-124N) EN 60950 sect. 2.5 and NEC Class 2 – Control equipment for hazardous location UL 60079-15 (Class I, Division 2, Groups A,B,C,D AEx n C II C T4 U) IEC/EN60 079-15(Class I, Zone 2, EEx nC II C T4 U), ( II3G EEX nAC IIC T4 (T3 with limited power) Safety approvals and certifications – CB report for IEC/EN 60950-1 – UL approvals UL 60950-1 rec. File: e181381, UL 508C listed File: e210002 – CSA certification (file no. 219759) for UL 60950-1, UL 508, UL 60079-15-02, ANSI/ISA 12.12.01, CSA-22.2 No. 60950-1-03, CSA C22.2 No. 107, CSA 60079-15-02 – II3G ATEX 94/9/EC certificate no. EPS 12 ATEX 1 424 X (option -EX only) – BG certification EN 60950-1, EN 60204-1, EN 61558-2-16, EN 50178 Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3 – Conducted RI suppression on input EN 55011 class B, EN 55022 class B, – Radiated RI suppression EN 55011 class B, EN 55022 class B, Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3 – Electrostatic discharge (ESD) IEC / EN 61000-4-2 4 kV / 8 kV criteria B – Radiated RF field immunity IEC / EN 61000-4-3 10 V / m criteria A – Electrical fast transient / burst immunity IEC / EN 61000-4-4 2 kV criteria B – Surge immunity IEC / EN 61000-4-5 1 kV / 2 kV criteria B – Immunity to conducted RF disturbances IEC / EN 61000-4-6 10 V criteria A – Power frequency field immunity IEC / EN 61000-4-8 30 A / m criteria A – Mains voltage dips and interruptions IEC / EN 61000-4-11 criteria B/C – Voltage sag immunity SEMI F47 Environment – Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10 – 55 Hz, 1 g, 1 oct/min – Shock acc. IEC 60068-2-27 3 axis, 15 g half sine, 11 ms |