Input voltage – nominal ranges 100 – 120 / 220 – 240 VACby selection switch – effective ranges 85 – 132 / 187 – 264 VAC – output power derating at input <100 VAC 3.3 %/V Input voltage frequency 47 – 63 Hz Harmonic limits EN 61000-3-2 Holdup time 10 ms min. Inrush current 70 A Recommended circuit breaker, characteristic C or fuse, slow blow type – TSP 080/120 6.0 – 16.0 A – TSP 240 10.0 – 16.0 A – TSP 480 16.0 – 25.0 A Efficiency 85 – 93 % |
Output voltage adj. range – 12 VDC models: 12 – 14 VDC – output power derating above 12 VDC : 10 %/V – 24 VDC models: 24 – 28 VDC – output power derating above 24 VDC : 5 %/V – 48 VDC models: 48 – 56 VDC – output power derating above 48 VDC : 2.5 %/V Boost output current – 120 %(at 24 VDC output voltage) – continuouse at <+50°C ambient temperature – power derating above 50°C ambient 2 %/°C – power derating at input <115 VAC 1.3 %/V – power derating at input <220 VAC 0.6 %/V (at upper input voltage range) Regulation – Input variation 1 % max. – Load variation (0–100 %) 1 % max. Ripple and Noise (20MHz bandwidth) 100 mVp-p typ. (200 mVp-p max.) Overload protection 120 – 140 % of Iout nom., constant current Short circuit current 90 % of Iout nom. (typ.), foldback Output overvoltage protection 45 V Over temperature protection switch off at overtemperature, automatic restart Power back immunity – 12 VDC models: 16 V (18 V for 1 sec.) – 24 VDC models: 35 V (40 V for 1 sec.) – 48 VDC models: 63 V (65 V for 1 sec.) Power OK signal – trigger threshold 12 VDC models: 10.0 – 11.5 V – 24 VDC models: 21.0 – 22.5 V – 48 VDC models: 42.0 – 45.0 V – output signal 12 VDC models: open collector 20 mA max. – 24 VDC models: open collector 10 mA max. – 48 VDC models: open collector 5 mA max. – Max. capacitive load unlimited Temperature range – output current derating above 60°C ambient 2.5 %/°C Humidity (non-condensing) 95 % rel. H max. Temperature coefficient 0.02 %/K Isolation according to IEC/EN 60950-1, UL 60950-1, UL 508 Safety standards – Information technology equipment IEC/EN 60950-1, UL 60950-1, CSA 22.2 No 60950-1-07 – Industrial control equipment UL 508, CSA- C22.2 No.107 – Electrical equipment for machines EN 60204-1 – Electronic equipment for power installation EN 50178 – Safety of transformers EN 61558-2-6, EN 61558-2-16 – Control equipment for hazardous location EN60 079-15II3G EX nA IIC T4 Safety approvals and certifications – CB scheme (IEC 60950-1) – UL approvals UL 60950-1, CSA 22.2 No. 60950-1-07 UL 508C listed File: e210002 – ATEX (for IP 54 enclosure) certificate no. EPS 10 ATEX 1 269 X – BG cert. (EN 61558-2-6/16, EN60950-1) Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3 – Conducted RI suppression on input EN 55011 class B, EN 55022 class B, – Radiated RI suppression EN 55011 class B, EN 55022 class B, Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3 – Electrostatic discharge (ESD) IEC/EN 61000-4-2 4 kV / 8 kV criteria B – Radiated RF field immunity IEC/EN 61000-4-3 10 V / m criteria A – Electrical fast transient / burst immunity IEC/EN 61000-4-4 2 kV criteria B – Surge immunity IEC/EN 61000-4-5 1 kV / 2 kV criteria B – Immunity to conducted RF disturbances IEC/EN 61000-4-6 10 V criteria A – Power frequency field immunity IEC/EN 61000-4-8 30 A / m criteria A – Mains voltage dips and interruptions IEC/EN 61000-4-11 criteria B/C Environment – Vibration acc. IEC 68-2-6; 3 axis, sine sweep, 10 – 55 Hz, 1 g, 1 oct/min – Shock acc. IEC 60068-2-27 3 axis, 15 g half sine, 11 ms |