| Operational Temperature | 0°C to 60°C (10°C to 40°C optimal) |
| Storage Temperature | -30°C to 60°C (0°C to 30°C optimal) |
| Relative Humidity-
Operational |
5% – 95% Non-Condensing
(Operational) |
| Ingress Protection | IP30 |
| Size | 42 x 42 x 20 mm (enclosure) |
| 42 x 42 x 21 mm (with bracket) | |
| Weight (including batteries) | 28g |
| Battery | CR2477 |
| External Connector (Base Variant) | Connector Type: JST A02ZR02ZR28H305B |
| £ 20Hz (Pulse Reading) | |
| Driven by open drain/relay contact |
| RF Power | 14 dBm |
| RF Sensitivity | up to -137dBm |
| LoRa Radio | SX1261 |
| Supported ISM Bands | NA915, EU868, EU433, AU915, AS923 |
| CN470, CN779, IN865, KR920, RU864 | |
| Antenna | Internal |
| LoRa Device Class | A |
| Sensor Function | PIR Variant | Base Variant |
| Motion Detection (PIR) | Y | |
| On/Off Magnet switch | Y | Y |
| Moisture/Leak Detection | Y | |
| Accelerometer | Y | Y |
| G-Force Measurement | Y | Y |
| On/Off External Contact | Y | |
| Light Detection | Y | Y |
| Temperature | Y | Y |
| Humidity | Y | Y |
| Operational Temperature | 20°C |
| Tx Power | 14 dBm |
| Rx Cycle/Hour | 1 |
| Transmission | SF 10
125 kHz |
SF 7
125 kHz |
SF 8
500 kHz |
|
| Base | 4 packets / hour | 4.8 | 11.2 | 13.0 |
| 3 packets / hour | 5.9 | 12.5 | 14.1 | |
| 2 packets / hour | 7.8 | 14.1 | 15.5 | |
| 1 packets / hour | 11.0 | 16.3 | 17.1 | |
| 1 packets / day | 18.5 | 19.0 | 19.1 |
| Safety | IEC 60950-1 (CE) |
| Regulatory | ETSI EN 300 220 |
| ETSI EN 301-489-1/-3 | |
| FCC 15.247 FCC 15.209 |