XEG7305 / XEG7306 / XEG7307 Switches
by Agatel
5/6/7-port Unmanaged Gigabit Ethernet switches with 4-PoE ports (booster) – Railway & ATEX Certified
Specifications
XEG7305 / XEG7306 / XEG7307 Switches
Key Features:
XEG7300 Series
5/6/7-port Unmanaged Gigabit Ethernet switches with 4-PoE ports (booster) – Railway & ATEX Certified
• Up to 5 10/100/1000 BASE-T(X) ports and 2 1000 BASE-X SFP ports
• Up to 4 802.3af or 802.3at compliant PoE ports
• Support 10K Jumbo frames
• Supports 802.3az Energy Efficient Ethernet for power savings
• Works from -40°C~70°C
• Failed power input alarm contact
• Certified by UL 61010-2-201 and UL C1D2/ATEX Zone 2
• EN50155 / EN50121-4 certified for Railway and Trackside applications
Technical Specifications
Model Name | XEG7305 | XEG7305-4P | XEG7306-1S | XEG7306-4P-1S | XEG7307-2S | XEG7307-4P-2S |
Switch Properties | ||||||
Processing Scheme | Store-and-Forward | |||||
MAC Address Table | 8096 | |||||
Jumbo Frame | 10K Bytes | |||||
Packet Buffer | 1 Mbits | |||||
Ethernet | ||||||
Compliance | IEEE802.3 for 10BASE-T IEEE802.3u for 100BASE-T(X) and 100BASE-FX IEEE 802.3ab for 1000BASE-T IEEE 802.3z for 1000BASE-X IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.3x Flow Control IEEE 802.3af / 802.3at for Power-over-Ethernet IEEE 802.3az for Energy Efficient Ethernet | |||||
Flow Control | Back pressure and pause frame-based flow control schemes | |||||
LLDP | Forwarding | |||||
Transmission Rate | 10/100/1000 Mbps (the second SFP port is 1000 Mbps only) | |||||
Auto MDI/MDI-X | Yes | |||||
Power | ||||||
Input Voltage | 12-52 VDC* | |||||
Input Current (System) | 0.5A @ 12 V | 0.6A @ 12V | ||||
Max. Power Consumption (System) | 6 W | 7.2 W | ||||
Input Current (with PoE) | – | 2.6A @ 51 V | – | 2.6A @ 51 V | – | 2.6A @ 51 V |
Max. Power Consumption (with PoE) | – | 130 W | – | 130 W | – | 130 W |
Relay Output | 24 V / 0.5A | |||||
Connector | Terminal Block | |||||
LED | ||||||
Indicators | PWR1, PWR2, Alarm, RJ45 Act/Link, SFP Link, PoE | |||||
Physical Characteristics | ||||||
Housing | IP30 protection according to EN 60529 | |||||
Material | SECC | Aluminum | ||||
Dimension (W x H x D) | 32 x 90 x 110 mm | 45.3 x 89.6 x 110 mm | ||||
Weight | 420g | 350g | ||||
Installation | DIN-rail or wall-mount (optional) | |||||
Environmental Limits | ||||||
Operating Temperature | -40°C~70°C (-40°F~158°F) | |||||
Storage Temperature | -40°C~85°C (-40°F~185°F) | |||||
Ambient Relative Humidity | 5%~95%, 55°C (Non-condensing) | |||||
*802.3af PoE output starts from 43 VDC input and 802.3at output starts from 51 VDC input.
Regulatory Approvals
Safety | UL 61010-2-201, UL C1D2/ATEX Zone 2 | ||||
EMC | EN 55032 | ||||
Rall Traffic | EN50155 / EN50121-4 | ||||
Test | Item | Value | Level | ||
IEC 61000-4-2 | ESD | Contact Discharge | ±8KV | 4 | |
IEC 61000-4-3 | RS | 80-1000MHz | 10(V/m) | 3 | |
IEC 61000-4-4 | EFT | AC Power Port | ±2.0KV | 3 | |
IEC 61000-4-5 | Surge | AC Power Port | Line-to Line±1.0KV Line-to Earth±2.0KV Line-to Line±1.0KV Line-to Earth±2.0KV Line-to Earth±2.0KV | 3 | |
IEC 61000-4-6 | CS | Conducted | 10 Vrms | 3 | |
IEC 61000-4-8 | PFMF | Enclosure | 30 A/m | 4 | |
IEC 61000-4-11 | DIP | AC Power Port | – | ||
Shock | MIL-STD-810F Method 516.5 | ||||
Drop | MIL-STD-810F Method 516.5 | ||||
Vibration | MIL-STD-810F Method 514.5 C-1 & C-2 | ||||
High Altitude | Certified for 4000m altitude according to IEC 60068-2-13 | ||||
RoHS | YES | ||||
MTBF | TBD | ||||
Warranty | 5 years | ||||
Downloads
- xeg7305-xeg7306-xeg7307-series Download
More Unmanaged Switches

XE2005 / XE2006 Switches
by Agatel
5/6-port Economy Unmanaged Fast Ethernet switches
Specifications
XE2316-2G SWITCHES
by Agatel
14+2Gb-Port Unmanaged Ethernet Switches
Specifications
XEG2308 Switches
by Agatel
8-port Unmanaged Gigabit Ethernet switch
Specifications
XL2300 Series
by Agatel
5-16 Ports Industrial Unmanaged Fast Ethernet Switches
Specifications
XLG2300 Series
by Agatel
5-26 Ports Industrial Unmanaged Gigabit Ethernet Switches
Specifications