Loading
Xceltra – reliability. engineered.
XEG6308 Switches

XEG6308 Switches

by Agatel

Industrial Unmanaged PoE Ethernet Switch

Specifications

XEG6308 Switches

Key Features:

 XEG6308 Series

Industrial Unmanaged PoE Ethernet Switch

• 8-Port 10/100/1000Mbps Gigabit Ethernet ports
• Supports P.S.E. based on IEEE802.3af/IEEE 802.3at
• Supports PoE Power up to 30 Watts for each PoE port
• Supports auto-negotiation and auto-MDI/MDI-X
• Supports store and forward transmission
• Supports flow control
• IP-30 metal case
• DIN-Rail and wall mounting (Optional)


 Technical Specifications

 

Technology

Standards

IEEE 802.3 for 10BaseT,

IEEE 802.3u for 100BaseT(X)

IEEE 802.3ab for 1000BaseT(X),

IEEE 802.3at/af for Power over Ethernet Technology

IEEE 802.3x for Flow Control

IEEE 802.3z for 1000BaseX

MAC Address Table

8K

Switching Latency

2.3us

Processing Type

Store and Forward

Flow Control

IEEE802.3x full duplex, back pressure flow control

Interface

RJ45 Ports

10/100/1000baseT(X),Auto MDI/MDI-X(Support Mode A)

Fiber Ports

1000Base SFP slot

LED Indicators

LAN(Steady green-Link up/Blinking-data transmitting & receiving), PoE(Yellow), PWR1(Green), PWR2(Green), Fault(Red)

Power Requirements

Dual Input

48 ~ 57 VDC (IEEE802.3af :48VDC input / IEEE802.3at :50~57VDC input)

Dual Inputs Current

Max. 3.1 A @ 55VDC (supports up to 4 ports at 30 W per PoE port)

Overload Current Protection

Present

Connection

Lockable 7-pin terminal blocks for power input

Reverse Polarity Protection

Present

Consumption

148.5W (with PoE full function)

Physical Characteristics

Housing

IP30 protection (>2.5mm objects, IEC60529), metal case (AL6063T5)

Dimensions (W x H x D)

53.4mm x 145.7mm x 119.9mm ( 2.10 x 5.74 x 4.72 in )

Weight

Approx 1000g

Installation

DIN-Rail mount kit, wall mount kit (optional)

Environmental Limits

Operating Temperature

-10°C ~ 70°C (14°F ~ 158°F)

Storage Temperature

-40°C ~ 85°C (-40°F ~ 185°F)

Ambient Relative Humidity

5% to 95% (non-condensing)

Notes: For UL policy the maximum operating temperature is 60°C, and the human body can tolerate maximum temperature is 70°C.

Environmental Limits

Safety

UL 60950-1

EMI

FCC Part 15 class A, CISPR(EN55032) class A

EMC

EN61000-4-2 (ESD), level 3

EN61000-4-3 (RS), level 3

EN61000-4-4 (EFT),level 3

EN61000-4-5 (Surge), level 3

EN61000-4-6 (CS), level 2

EN61000-4-8 (PFMF)

EN61000-4-11 (Dips)

Shock

MIL-STD-810F Method 516.5

Freefall

MIL-STD-810F Method 516.5

Vibration

MIL-STD-810F Method 514.5 C-1 & C-2

MTBF

Warranty

5 years

 Regulatory Approvals

 

EMI Immunity Type Tests

Test

Description

Test Levels

Severity Levels

FCC part 15

–

Subpart B

–

class A

EN55032

–

2012+AC:2013

–

class A

EMS Tests

Test

Description

Test Levels

Severity Levels

IEC61000-4-2

 

ESD

Contact discharge

6 KV, Criterion B

level 3

Air discharge

8 KV, , Criterion B

level 3

IEC61000-4-3

RS

Enclosure ports

10 V/m (80 – 1000 MHz),

Criterion A

 

level 3

IEC61000-4-4

EFT

Power Line

2 KV, Criterion B

level 3

IEC61000-4-5

Surge

Signal Port

2 KV, Criterion B

level 3

Power Line

2 KV, Criterion B

level 3

IEC61000-4-6

CS

Signal Port

3 V (0.15 – 80 MHz), Criterion A

10 V (0.15 – 80 MHz), Criterion A

level 2

Power Line

level 2

Safety Tests

Test

Description

Rating

Severity Levels

UL60950-1

–

2nd Edition, 2007-03-27

48-57 V DC, 3.1A max

–

CSA C22.2 No.60950-1-07

–

2nd Edition, 2007-03

48-57 V DC, 3.1A max

–

CB

–

IEC 60950-1:2005 second version

48-57 V DC, 3.1A max

–

Environmental Type Tests

Test

Description

Test Levels

Severity Levels

MIL-STD-810F

Shock

Impact acceleration & Pluse duration

40g @ 11ms

–

MIL-STD-810F

Freefall

8 corners, 12 edges, 6 faces

122 cm

–

MIL-STD-810F

Vibration

Packaged Random waveform

x: 2.4 Grms
y: 1.28 Grms
z: 3.85 Grms

–

Operating Random waveform

x: 0.740 Grms
y: 0.204 Grms
z: 1.04 Grms

–